Skip to main content
[email protected]
Menu
Language
Appearance

Why “We Support HL7” Is Not Enough: A Buyer’s Field Guide

ASAzHeC Standards Desk
June 2, 2026
3min read
WhatsAppEmail

“We support HL7.” “We’re FHIR-enabled.” “Fully interoperable.” Arizona organizations evaluating health-IT products hear these phrases constantly, and they are nearly meaningless on their own. Interoperability is not a checkbox; it is a set of specific, testable capabilities. This field guide offers the questions that turn a vague claim into a verifiable answer — written from a vendor-neutral standpoint, because no product is named or endorsed here.

The problem with the claims

“HL7” names a standards organization that publishes many standards — HL7 v2 messaging, the C-CDA document standard, and FHIR among them. Saying a product “supports HL7” does not say which. “FHIR-enabled” can mean anything from a fully profiled, US Core-conformant API to a single read-only endpoint. The vagueness is not always deceptive, but it is never sufficient for a purchasing decision.

Questions for any interoperability claim

Ask these, and expect specific answers:

  • Which standard, which version? HL7 v2? FHIR R4? C-CDA? “All of the above” deserves follow-up on each.
  • For FHIR: which US Core version? Conformance to a stated US Core release is what makes endpoints behave predictably. A vendor who cannot name a version is telling you something.
  • Which USCDI data is actually supported? This is the difference between an API that exists and one that returns the data you need.
  • What has it been tested against? Real exchange partners, a recognized testing process, or only the vendor’s own lab? Untested conformance is a hope, not a fact.
  • How does it handle identity and consent? Patient matching and consent enforcement are where interoperability gets dangerous if done poorly.

For device and supply integration, add

  • How is device data coded? Are measurements carried with LOINC codes, or as uncoded values that cannot be trended or aggregated?
  • Is UDI captured and carried forward? For device-bearing workflows, does the system hold the device identifier in a usable field, or only in free text?

What good answers look like

A capable vendor answers these crisply: a named standard and version, a stated US Core conformance, a specific USCDI baseline, evidence of testing against outside partners, and a clear account of identity and consent handling. Evasiveness on any of them is itself informative.

The neutral-table value

AzHeC names no products and recommends no vendors. What we offer Arizona organizations is the literacy to evaluate claims on their merits — to ask the questions above and recognize a real answer from a deflection. That literacy is the most durable protection a buyer has. Start with the plain-language primers in our Standards work area, and keep the glossary of Health IT terms handy as you read the responses you get back.

AS

Written by

AzHeC Standards Desk

Join Our Community

Connect with like-minded readers, share your thoughts, and engage in meaningful discussions.

Explore More Articles

Discover our extensive library of health research and evidence-based insights.

Explore Related Topics

Comments

0

Sign in to join the discussion

Share your thoughts and engage with the community

No comments yet

Sign in to be the first to comment!